2-INSTALLATION INSTRUCTIONS

In the case of paired products, the solid combustibility or upper storey chimneypot must be at least 50 cm higher than the

others in order to prevent the pressure from being transferred between the paired chimneypots.

The chimneypot must not have any obstacles within a range of 10 metres, such as walls, slopes and trees. Otherwise, raise

it by at least 1 m above the obstacle and in the case of other chimneypots nearby, leave a gap of at least 2 m. In any case,

the chimneypot must exceed the highest point of the roof by at least 100 cm or be above the reflux area, which is equal to

130 cm in roofs with a gradient greater than 10° (height perpendicular to the surface of the roof).