Operation, Do not expect heating efficiency immediately – MCZ Forma Wood 75 Dx User Manual

Page 25

Advertising
background image

23

5-OPERATION

START-UP PRECAUTIONS

Make sure you have read and fully understood the contents of this instruction manual.

Remove all components that could burn from the firebox and door (instructions and various adhesive labels).

Remove the stickers from the ceramic glass otherwise the high temperature could melt them and cause irreparable damage to the glass.

The product can be positioned at an angle or against the wall.

Avoid touching the product during the initial start-up, as the paint completes its drying process and hardens during

this phase. It is good practice to guarantee effective ventilation in the room during the initial start-up, as the

product will emit some smoke and smell of paint, which is absolutely normal!

If necessary, touch up the paint with the spray can of the specific colour.

Do not stand close to the product and air the room. The smoke and smell of paint will disappear after about an hour of operation, however,

remember they are not harmful in any case.

The product will be subject to expansion and contraction during the start-up and cooling phases, therefore light

creaking noises may be heard.

This is absolutely normal as the structure is made of laminated steel and must not be considered a defect.

It is extremely important to make sure the product is not immediately overheated and the temperature increases

gradually.

This will prevent damaging the welds and the steel structure.

Do not expect heating efficiency immediately!

OPERATION TEST

ATTENTION !!

BEFORE PERFORMING ANY CLADDING ASSEMBLY OPERATION, CARRY OUT A GENERAL TEST ON THE FIREPLACE

FOLLOWING THE POINTS BELOW:

• Lift and lower the hearth door 7-8 times to check that it slides smoothly and that the counterweights do not cause any noise against

the structure.

• Check that all wiring and the control unit (if one fits the COMFORT AIR VF kit) are distant from the hot body of the closed fireplace.

• Test at all speeds and ventilation kit modalities (if one fits the COMFORT AIR VF kit).

• Light the fire with moderation, to check that the smoke fitting has no smoke/soot leaks.

THE MANUFACTURER DECLINES ALL LIABILITY FOR DAMAGE TO THE CLADDING IF THE PREVENTIVE CHECKS ABOVE ARE

NOT CARRIED OUT, RESULTING IN THE DEMOLITION OF THE CLADDING ITSELF TO PERFORM REPAIRS OR ADJUSTMENTS.

STAGES FOR THE FIRST START-UP TEST

• Make sure you have read and fully understood the contents of this instructions manual.

• Remove all components that could burn from the closed fireplace firebox and door (instructions and various adhesive labels).

• Remove the stickers from the ceramic glass otherwise the high temperature could melt them and cause irreparable damage to the

glass. In this case the manufacturer will not guarantee the glass.

• Open the front combustion air damper completely using the hook supplied.

• Position small sized and thoroughly dry wood (moisture 15/20%). Light the fire on moderate power without heating the structure

excessively. Any smells from processing and/or evaporation residues will be emitted the first few times the fireplace is lit and will

disappear after it has been used a few times on full power.

Technical Dept. - All rights reserved - Reproduction is prohibited

Advertising