4-INSTALLATION AND ASSEMBLY

FLUE CONNECTION

It is recommended to connect the closed fireplace to the flue via aluminised steel pipes and bends able to resist the high temperatures that

are reached in that tract and smoke corrosion. These connections are available upon request in various sizes (see our price list) and simplify

installation as they are assembled by fitting one inside the other. (fig.7)

Any increases in the section of the fitting must be performed directly over the hood of the fireplace and not along

the chimney flue. Once the installation is complete, it is mandatory to insulate the smoke fitting with ceramic fibre

blanket or material resistant to at least 600° C.

CLADDING AND COUNTER HOOD ASSEMBLY

READ THE "OPERATION TEST" CHAPTER BEFORE STARTING ANY FIREPLACE CLADDING OPERATION.

The closed fireplace and the cladding parts must be fastened together WITHOUT COMING INTO CONTACT WITH THE STEEL STRUCTURE

in order to prevent heat from being transmitted to the marble and/or stone and to allow for normal thermal expansion. Pay attention to

the wood finishes, such as beams or shelves.

It is recommended to set up the counter hood made of 15 to 20 mm thick fireproof plasterboard with a freestanding frame

FIGURE 7 - CHIMNEY FLUE FITTING

FIGURE 8 - BEAM INSULATION

1.

INSULATION APPLIED OR TO BE APPLIED

2.

BEAM MADE OF WOOD

3.

MARBLE OR OTHER MATERIAL

Technical Dept. - All rights reserved - Reproduction is prohibited