Examples of flue pipes, Important – MCZ Vivo 70 Wood User Manual

Page 10

Advertising
background image

Chapter 2

INSTALLATION AND USE MANUAL

page

10

Theoretical notions for installation

Technical service – MCZ Group S.p.A. all rights reserved - Reproduction prohibited

2.5.1. Examples of flue pipes














Square or rectangular section flue pipes must have rounded internal

corners with radius not less than 20mm. For the rectangular section,

the ratio between internal dimensions must be ≤1.5.
The sections/lengths of the flue pipe shown in the technical data table

are guidelines for correct installation. Any alternative configurations

must be suitably sized in accordance with EN13384-1.
The smoke duct should be equipped with a solid material collection

chamber at the mouth of the smoke duct to be easily opened with an

airtight door.

IMPORTANT !

In the event of doubt on your chimney flue operations or

that its dimensions are different from those recommended,

we highly suggest an authorised MCZ technician inspect and

measure chimney flue performance (micro-gauge

measurements)
MCZ s.p.a. shall not be held liable for poor operation of the

fireplace stove that is due to a flue pipe of improper size or

installation that does not comply with provided

requirements.




AISI 316 stainless steel flue

pipe with dual chamber

insulated with ceramic wool

or equivalent resistant to

400°C.
EXCELLENT

Flue pipe in refractory brick

with insulated double wall and

external coat of cement mix

lightened with honeycomb

material such as clay.
GOOD

Traditional square section

clay flue pipe with insulating

hollow inserts.
GOOD

Avoid flue pipes with internal

rectangular sections whose

larger side is double the smaller

such as 20x40 or 15x30.
AVERAGE

Advertising