6.4. FIRST LIGHTING

It is advisable to approach the first lighting with caution, using

good-quality, well-seasoned wood.
The primary air inlet must be fully open. Do not use alcohol,

petrol, or other volatile flammable substances. On first lighting,

fumes and unpleasant smells may be given off, caused by the drying of

the product; this is not hazardous to the health, and it is sufficient to

ventilate the room adequately. Once combustion has started, pieces of

wood of normal size may be added.
The flame must have as far as possible a smooth and laminar flow. On

the various occasions when the stove needs reloading, the

door should be opened slowly, to avoid blowbacks of smoke

into the room.
Proceed as follows:

Place a small amount of balled paper in the stove.

Cover the paper with a small quantity of twigs and a few pieces of

wood.

Open the primary air register completely (turn completely to the

left) fig.14

Light the paper and if necessary leave the door open to the first

stage.

When the twigs are burning, the door can be closed.

Only once the flame is burning well (presence of a bed of coals and

full combustion), place the air adjustment between the two flames

(see fig.14) large flame to obtain nominal power, small flame for

slow combustion.


As the fire burns, add wood. Never overload the fireplace stove

with wood (see technical specifications in the table).
As soon as the flames have died down and a bed of embers has

formed, load the stove normally. Small loads of wood are preferable to

large ones for combustion.

Attention

Do not use volatile, flammable substances

(petrol, alcohol etc.) for lighting the fire.

Do not use fuels which could release toxic

substances or pollutants.

Do not put the fire out by throwing water on it.

Check the external and internal air intakes, and

the flue pipe, at least once a year, arranging for

them to be cleaned.

During use, the metal parts and the glass reach

high temperatures. For all jobs of loading the

stove, adjustment or cleaning the ash drawer,

use the insulating glove provided.

Never leave children unattended near the

fireplace stove when it is in use.

The risk of burns from contact with hot surfaces

is very high.

Figure 15 - Door open to first stage