MCZ Vivo 70 Wood User Manual

Page 7

Advertising
background image

Chapter 2

INSTALLATION AND USE MANUAL

page

7

Theoretical notions for installation

Technical service – MCZ Group S.p.A. all rights reserved - Reproduction prohibited

2. INSTALLATION IN ACCORDANCE WITH UNI

10683

2.1. OPERATING AREA

For good operations and good heat distribution, the fireplace stove

should be positioned in a place where the air required for combustion

can flow (at least 60 m

3

/h must be available) according to installation

standards and current regulations in the country of installation.

The room volume must not be less than 60 m

3

.


Air must enter through permanent apertures on the walls (near the

fireplace stove) that open outdoors with a minimum section of 360 cm

2

.

These apertures (air vents) must be made so as not to be obstructed in

any way.
Air can also be taken from adjacent rooms as long as these are

equipped with outdoor air vents and not bedrooms or bathrooms or

rooms where fire hazards do not exist such as garages, wood sheds,

flammable material warehouses, strictly observing the provisions of

current regulations.

Fireplace stoves may not be installed in

bedrooms, bathrooms and where another

heating device is installed without autonomous

air flow (fireplace, stove, etc.).

Placing the fireplace stove in explosive

environments is prohibited.

The floor of the room where the fireplace stove

is to be installed must be strong enough to

support its weight.

In the event of wood floors, install a protective

covering in accordance with current regulations

in the country of installation.

If walls are not flammable, install the fireplace

stove at least 5 cm from the walls.

2.2. PRECAUTIONS

The fireplace stove must be installed in a suitable surface that permits

routine opening and maintenance operations.
The room must be:

suitable for room operating conditions

equipped with an adequate smoke exhaust system

equipped with outdoor ventilation

Advertising
This manual is related to the following products: