Ba c c, Ab c c – MCZ Vivo 70 Wood User Manual

Page 16

Advertising
background image

Chapter 4

INSTALLATION AND USE MANUAL

page

16

Installation and assembly

Technical service – MCZ Group S.p.A. all rights reserved - Reproduction prohibited

4.2.1. Natural convection (COMFORT AIR VN)

If this system is used, the installer must make a connection to the

outside (B) concerning the inlet of combustion air (fig.2), and an air

intake (A) for the inlet of fresh ventilation air inside the cladding.
For the ducting of hot air C, it is necessary the install the hoses Ø 150

mm C (optional) on the flanges located on the upper part of the stove

unit

ATTENTION!
FOR BEST OPERATION, MCZ STRONGLY SUGGESTS

CONNECTION THE COMBUSTION AIR INTAKE Ø100

DIRECTLY TO AN EXTERNAL AIR INTAKE.

4.2.2. Forced convection (COMFORT AIR VF)

Also in this case, it is necessary to connect the stove unit to an external

air intake (B) with a pipe Ø 100 (optional) using the flange located on

the back of the stove unit. (figure 1) If it is not possible to connect

directly to the air intake, at least connect the flange to the outside of

the cladding.
This operation is necessary to ensure proper operation of the

COMFORT AIR KIT. If the combustion air intake is not connected

directly to the an external air intake (B), it will be obligatory to provide

an air intake (A) that has a free passage of not less than 150 cm

2

so

that natural fresh air flows into the room of installation (preferably

inside the cladding).Figure 3
For the ducting of hot air, it is necessary to install a reduction flange Ø

100 on the upper connections of the stove unit. Then insert in the

flanges of the hoses Ø 100 the COMFORT AIR outlets (C).
Then proceed as set forth in

paragraph 5.3 “Installation of comfort air

kit".

ATTENTION!
FOR BEST OPERATION, MCZ STRONGLY SUGGESTS

CONNECTING THE COMBUSTION AIR INTAKE Ø100

DIRECTLY TO AN EXTERNAL AIR INTAKE OR AT

LEAST TO HAVE AIR DRAWN FROM OUTSIDE THE

CLADDING.

Figure 2 – Natural convection

A

B

C

C

B

A

C

C

Figure 3 – Forced convection

Advertising
This manual is related to the following products: