MCZ Vivo 70 Wood User Manual

Page 32

Advertising
background image

Chapter 5

INSTALLATION AND USE MANUAL

page

32

Comfort air kit

Technical service – MCZ Group S.p.A. all rights reserved - Reproduction prohibited

5.7. CONNECTIONS

























LINE (1-2 LINEA)
FAN 1 (3-4 VENTIL.)
FAN 2 (5-6VENTIL.)
LIGHT (7-8 AUX)
SWITCH FOR DOOR OPENING (9-10 PORT.)
PROBE (11-12 SONDA)
TERMINAL FOR EARTHING (A)


Connect fans 1 and 2 to the corresponding terminals on the control unit

(3-4 and 5-6).
Connect the probe (11-12); see paragraph 5.6.
For air outlet with light, connect the power cord to the control unit on

the terminals (7-8). For air outlets with a light for natural ventilation,

make the connection to a dedicated switch.
Connect the power cord of the control unit (1-2) to the 230V 50HZ

mains socket.
Once the connections have been made, activate MAN

  operation and

try turning on the fans to see of they all work. Turn the knob right and

left to test the various speeds.
When connections are complete, install the selected air outlets.

11-12

A

7-8

7-8

5-6

3-4

Advertising