Rate input – Precision Digital PD6300 User Manual

Page 10

Advertising
background image

Model PD6300 Pulse Input Rate/Totalizer

Instruction Manual

10

OVERVOLTAGE
CATEGORY

Installation Overvoltage Category II:
Local level with smaller transient overvoltages than Installa-
tion Overvoltage Category III.

ENVIRONMENTAL Operating temperature range: -40 to 65°C

Storage temperature range: -40 to 85°C
Relative humidity: 0 to 90% non-condensing

CONNECTIONS

Removable screw terminal blocks accept 12 to 22 AWG
wire, RJ45 for external relays, digital I/O, and serial com-
munication adapters.

ENCLOSURE

1/8 DIN, high impact plastic, UL 94V-0, color: black

MOUNTING

1/8 DIN panel cutout required:
3.622" x 1.772" (92 mm x 45 mm)
Two panel mounting bracket assemblies are provided.

TIGHTENING
TORQUE

Screw terminal connectors: 5 lb-in (0.56 Nm)

OVERALL
DIMENSIONS

4.68" x 2.45" x 5.64" (119 mm x 62 mm x 143 mm)
(W x H x D)

WEIGHT

9.5 oz (269 g)

WARRANTY

3 years parts & labor

Rate Input

INPUTS

Field selectable: Pulse or square wave 0-5 V, 0-12 V, or
0-24 V @ 30 kHz; TTL; open collector 4.7 k

 pull-up to 5 V

@ 30 kHz; NPN or PNP transistor, switch contact 4.7 k

pull-up to 5 V @ 40 Hz; Modbus PV (Slave)

LOW VOLTAGE
MAG PICKUP
(Isolated)

Sensitivity: 40 mVp-p to 8Vp-p

MINIMUM INPUT
FREQUENCY

0.001 Hz
Minimum frequency is dependent on high gate setting.

MAXIMUM INPUT
FREQUENCY

30,000 Hz (10,000 for low voltage mag pickup)

INPUT
IMPEDANCE

Pulse input: Greater than 300 k

 @ 1 kHz.

Open collector/switch input: 4.7 k

 pull-up to 5 V.

ACCURACY

±0.03% of calibrated span ±1 count

TEMPERATURE
DRIFT

Rate display is not affected by changes in temperature.

MULTI-POINT
LINEARIZATION

2 to 32 points

LOW-FLOW
CUTOFF

0-999999 (0 disables cutoff function)

Advertising