Precision Digital PD6300 User Manual

Page 47

Advertising
background image

Model PD6300 Pulse Input Rate/Totalizer

Instruction Manual

47

Gate Settings

Slow Pulse Rate

Low Gate* (sec)

High Gate (sec)

Min Freq** (Hz)

1.0 2.0 0.5000
1.0 10.0 0.1000
1.0 20.0 0.0500
1.0 100.0 0.0100
1.0 200.0 0.0050
1.0 400.0 0.0025
1.0 800.0 0.0012
1.0 999.9 0.0010

*The low gate setting corresponds to the display update rate and is
used to stabilize the display reading with a fluctuating signal.
**The minimum frequency is dependent on high gate setting.

Contact De-Bounce Filter (FiLter)

The filter function (FiLter) can be used for applications where the meter
is set up to count pulses generated by switch contacts. The filter value
can be set anywhere between 2 and 50, the higher the value, the greater
the filtering.
The filter function (Filter) is the second option in the Advanced Fea-
tures menu. There are two settings, Hi SPd (high speed) and Lo SPd
(low speed), press ENTER when Lo SPd is displayed to enable the filter
function. Program the filter value, so that there are no extra counts when
a contact closure is completed.

Filter Settings

Contact De-Bounce Filter

Filter Setting

Speed Setting

Max Freq (Hz)

2 Lo

SPd 999

4 Lo

SPd 499

8 Lo

SPd 249

16 Lo

SPd 124

32 Lo

SPd 62

40 Lo

SPd 50

50 Lo

SPd 40

N/A Hi

SPd 30,000

Advertising
This manual is related to the following products: