Ind. LuNAR RK200DTG3 Installation

Guide

17

Relay Mode Configuration (DIP
switch 6=OFF)

:

1

2

3

4

5

6

7

ACT LED Green

Line

Self

Test AM

RELAY

MODE

REMOTE

CONTROL

8

9

N/A N/A

ON

DIP switch
Number

Description

1

Used to determine the operation of the ACT
DIP switch ON: ACT is enabled
DIP switch OFF: ACT is disabled (default factory)

2

Used to determine the operation of the detector’s LEDs
Dip switch ON: LEDs are enabled (default factory)
DIP switch OFF: LEDs are disabled

3

Used to determine the operation of the "Green Line" (See Note below)
DIP switch ON: "Green Line" is enabled
DIP switch OFF: "Green Line" is disabled (default factory)

4

Used to determine the type of Self Test (See Note below)
DIP switch ON: Local Self Test:
In case the local self test fails, the FAULT/AM Relay is activated for a period of 2.5 secs.
DIP switch OFF: Remote Self Test (default factory):
In case the remote self test passes, the Alarm Relays are activated for a period of 5 secs.
In case the test fails, FAULT/AM Relay is activated for a period of 2.5 seconds.

5

Used to determine whether Active IR Anti-Masking is active. (See Note below)
DIP switch ON: Enable
DIP switch OFF: Disable (default factory)

IMPORTANT:

If the AM is enabled via DIP Switch 5, the cover must be fitted within 1 minute from applying the
power. If the detector is already powered up and DIP Switch 5 is turned on, the unit must be
down powered to reset the AM calibration.

6

Used to determine the detector’s connection mode

DIP switch OFF: Relay mode

7

Used to determine if the Remote Control communication is enabled or disabled.
DIP switch ON: RC communication is always enabled.
DIP switch OFF:

RC

communication

depends on the voltage applied to the terminal block

“RC”

(default factory)

When an activation signal is applied to the RC input of the terminal block, RC is enabled.

IMPORTANT:

Turn dipswitch 7 “OFF” after installation and when leaving the site for security reasons. This
will prevent unauthorized use of a remote control unit that may be used to disable the detector.

8-9

DIP switches OFF

NOTE:

See Set Terminal Blocks for activation details.