Specifications – RISCO Group Industrial LuNAR User Manual
Page 24
Ind. LuNAR RK200DTG3 Installation Guide
22
Specifications
Coverage
Coverage pattern consists of 192 fingers (96 Fresnel facets)
divided into 3 lens sections.
Each lens section has 4 adjustable vertical positions for variable
mounting height and customized coverage.
360° by 18m (60ft) diameter. When mounting the detector under
3.7m, the coverage diameter starts to decrease up to 15m (50ft).
Variable Mounting Height
From 2.7m to 8.6m (9’ to 28’), 4 lens positions according to
installation height
RFI immunity
According to EN50130-4
Operating voltage
9 to 16VDC
Current consumption
20mA at 12VDC, 30mA at 16 VDC, Maximum 40mA with all
LEDs on.
Alarm and AM contacts
Opto-relay NC, 100mA, 24 VDC
Tamper contacts
NC, 500mA, 24 VDC
Alarm Time
2.2 seconds
Warm-up time
2 minutes
Optical Filtering for white
light
protection
Pigmented Fresnel lens
Operating temperature
-20° C to 55° C (-4° F to 131° F)
Storage temperature
-20° C to 60° C (-4° F to 140° F)
Dimensions (Height x
Diameter)
99mm x 194mm (3.9’’x 7.6’’)
The Ind. LuNAR RK200DTG3 detector is suitable for use in
installations complying with PD6662, EN50131-1 and EN50131-