Ind. LuNAR RK200DTG3 Installation Guide

22

Specifications

Coverage

Coverage pattern consists of 192 fingers (96 Fresnel facets)
divided into 3 lens sections.
Each lens section has 4 adjustable vertical positions for variable
mounting height and customized coverage.
360° by 18m (60ft) diameter. When mounting the detector under
3.7m, the coverage diameter starts to decrease up to 15m (50ft).

Variable Mounting Height

From 2.7m to 8.6m (9’ to 28’), 4 lens positions according to
installation height

RFI immunity

According to EN50130-4

Operating voltage

9 to 16VDC

Current consumption

20mA at 12VDC, 30mA at 16 VDC, Maximum 40mA with all
LEDs on.

Alarm and AM contacts

Opto-relay NC, 100mA, 24 VDC

Tamper contacts

NC, 500mA, 24 VDC

Alarm Time

2.2 seconds

Warm-up time

2 minutes

Optical Filtering for white
light
protection

Pigmented Fresnel lens

Operating temperature

-20° C to 55° C (-4° F to 131° F)

Storage temperature

-20° C to 60° C (-4° F to 140° F)

Dimensions (Height x
Diameter)

99mm x 194mm (3.9’’x 7.6’’)

The Ind. LuNAR RK200DTG3 detector is suitable for use in
installations complying with PD6662, EN50131-1 and EN50131-
2-4 Grade 3, Class II.

Advertising