Ind. LuNAR RK200DTG3 Installation Guide

6

INSTALLATION

Preliminary steps:

Before installation, study the space to be protected carefully in order to choose the exact
location of the unit for the best possible coverage.

Never install the Ind. LuNAR RK200DTG3 in an environment that causes an alarm condition
in one technology.

Avoid installations where rotating machines (e.g. fans) are normally in operation within the
coverage pattern. Point the unit away from glass exposed to the outdoors and objects that
may change temperature rapidly.

Do not mount the detector in direct sunlight or near any heat sources. Detection sectors
should be pointed either towards a wall, floor but not towards windows or curtains. The
installation surface should be solid, smooth and vibration free

Eliminate interference from nearby outside sources.

For optimum detection, select a location likely to intercept an intruder moving across the
coverage pattern.

Recommended mounting heights that allow 18m (60ft) detection, are from 3.7m to 8.6m.

The detector must be mounted on the ceiling, preferably in the center of the room.