Figure 13: Model 3300 fan and Fan Top (Fan Top shows the 3300SR model).

To connect the 3300(SR) to the DM-2 Digital Pressure Gauge

1. Connect Speed Control Cable from the DM-2 umbilical to the Control Port on the variable speed drive (red

box containing power supply).

2. Connect the pressure tubes from the DM-2 umbilical to the matching-color ports on the variable speed drive

(some drives do not have color-coded ports – in these cases, attach using pressure port naming conventions
on the DM-2). If the variable speed drive does not have pressure ports, connect the color-coded tubes to
the matching colored tubes on the Fan umbilical.

3. Connect the power cord from the variable speed drive to a 20A compatible wall outlet. The 3300 fan draws

a significant amount of power; no other devices can be running on the same circuit.

4. Connect a pressure tube from the “Ref B” (yellow) port on the variable speed drive to the “Ref B (-)” (yellow)

port on the DM-2.

5. If available, connect a second pressure tube from the “Input B” port (green) on the variable speed drive to

the “Input B (+)” (green) port of the DM-2.

6. Connect the Speed Control Cable from the umbilical to the “Speed Control“port on the DM-2.

2.3

Model 200 (DucTester) or 300 fans for tight houses

To turn a duct testing system (DU200, DE200, DK200) into a Door Fan system for testing tight enclosures (US200,
EU200, and UK200), you only need to add an Aluminum Frame and a Low-Flow Cloth Door Panel.