Retrotec Blower Door User Manual

Page 61

Advertising
background image

Page 61 of 87
©Retrotec Inc. 2015

Table 8: Retrotec 1000/2000/3000 series fans. Building Pressure: 10 Pa. Flow: AWAY from the operator. Units in CFM.

Fan

Pressure

(Pa)

Open

A

B

C8

C6

C4

C2

C1

L4

L2

L1

10

1784

875

553

251

191

123

65

39

12

7

3

12

1950

953

606

275

210

136

73

43

14

7

4

14

2103

1026

654

297

228

148

80

47

15

8

4

16

2247

1094

700

317

245

159

87

51

16

8

4

18

2382

1158

742

336

260

170

94

55

16

9

5

20

2511

1218

782

354

275

180

100

58

17

9

5

22

2633

1276

820

372

289

189

105

62

18

10

5

24

2750

1331

857

388

302

198

111

65

19

10

5

26

2863

1384

892

404

315

206

116

68

20

11

6

28

2971

1435

925

419

327

215

121

71

20

11

6

30

3076

1485

958

434

339

223

126

73

21

11

6

32

3177

1532

989

448

351

230

131

76

22

12

6

34

3276

1579

1020

462

362

238

135

79

22

12

7

36

3371

1624

1049

476

372

245

140

81

23

13

7

38

3464

1668

1078

489

383

252

144

84

24

13

7

40

3555

1711

1106

502

393

259

148

86

24

13

7

42

3643

1752

1133

514

403

266

153

89

25

14

7

44

3729

1793

1160

527

413

272

157

91

25

14

7

46

3813

1833

1186

539

423

279

161

93

26

14

8

48

3896

1872

1212

550

432

285

164

95

26

14

8

50

3977

1910

1237

562

441

291

168

98

27

15

8

52

4056

1948

1261

573

450

297

172

100

27

15

8

54

4133

1984

1285

584

459

303

176

102

28

15

8

56

4209

2021

1309

595

467

309

179

104

28

16

8

58

4284

2056

1332

606

476

315

183

106

29

16

9

60

4358

2091

1355

617

484

320

186

108

29

16

9

Advertising