Power supply interior status light fault codes, 4 power supply interior status light fault codes – Retrotec Blower Door User Manual

Page 57

Advertising
background image

Page 57 of 87
©Retrotec Inc. 2015

Figure 35: Relay box in the variable speed drive.

Ensure that the relay is seated properly. The relay may require gluing with silicon glue. The case cover screws will
need to be removed in order to access the relay. Remove the tamper seal, if so equipped. Remove the front left
side and right side, top and bottom screws. Also remove the rear left and right bottom screws. Loosen the rear top
screws, but do not remove them. The cover can then be swung upward.

8.4

Power supply interior status light fault codes

You can see the lights by looking through the holes in the right side of the power supply. The lights are toward the
rear of the power supply.

The PWR (Power) LED is the LED to the right. This LED is solid green when AC is applied to the power supply.

The ST (Status) LED is the LED to the left. This LED will indicate an abnormal or fault condition. The information can
be used to diagnose an installation problem such as incorrect input voltage, an overload condition, and power
supply output mis-wiring. It will also provide a signal which informs the user that all power supply and
microcontroller operating parameters are normal.

Table 7: Power supply status light indications

Status LED

Color

Flash Rate

Power supply Status

Color and Sequence After Recovered Fault

Green

1 sec on/off

Normal operation

--

Red

On

Overload

Green

Red

¼ sec on/off

Power supply timed out --

Red

1 sec on/off

Short circuit

--

Red/Yellow

¼ sec on/off

Under voltage

Red/Yellow/Green

Red/Yellow

1 sec on/off

Over voltage

Red/Yellow/Green

Yellow

On

Stop

--

Yellow

0.04 s on/0.06 s off

Phase Loss Detection

--

Relay
Box

Advertising