33. Tighten the impeller with a rubber mallet by hitting on

one of blades in a clockwise position until tight.

34. The casting marks on the pump back plate indicate

where the volute must be placed. Make sure that the

volute is placed correctly inside these marks.

35. After installing the rubber gasket on the face of the

volute, place the volute on the pump back plate. Tip

the unit back slightly to hold it in position.

36. Make sure there is enough clearance between the

volute and impeller, use a feeler gauge to check the

gap. While holding the volute tightly against the pump

back plate, insert different size feeler gauge blades

until the correct reading is obtained.

The recommended clearance is 0.024 to 0.039