45. Remove the discharge nozzle and inspect the gasket

and nozzle for cracks.

46. When replacing the gasket, make sure the gasket is

fl at and not kinked. The gasket does not have a speci-

fi ed side for placing on the pump housing.

43. Once the case is torqued down, pull the recoil starter

to check that pump and engine turn over freely. If OK,

then

re-fi ll with prime water. Next check the engine oil

and start the engine. Apply vacuum pressure plate tes-

ter per service manual, and check for leaks.

44. If it becomes necessary to remove the discharge noz-

zle, the following procedure is recommended. Loosen

and remove the 4 bolts that hold the nozzle housing to

the outer casing.