55. After replacing discharge nozzle, loosely and

evenly tighten the four bolts that hold it to the pump

housing. Torque the bolts to the specifi ed value of:

PKX201T-3 to 4 ft. lbs.

PKX301T-4 to 6 ft lbs.

56. Should it become necessary to remove the top pump

housing cover, follow the listed procedure. Remove

the four bolts that hold the cover in position

and lift cover off.

53. The picture shows the correct position of the discharge

nozzle. The elongated portion of the discharge

nozzle will be on the bottom.

54. Apply a high temperature thread sealant such as:

Permatex® High Temperature Thread Sealant to the

4 bolts that hold the discharge nozzle to the pump

housing. This will prevent leakage due to vibration,

temperature cycling, and extreme pressure. This type

of sealant protects against rust, corrosion, and galling

of threads. It is service replaceable.