Thermo Pride Gas/Propane Furnace Mobile Home CMC1 User Manual

Page 54

Advertising
background image

All installations and services must be performed by qualified service personnel.

52

If the sensed failure is in the system (external to the control), the LED will flash in the
following flash-pause sequences to indicate failure status (each flash will last
approximately 0.25 seconds, and each pause will last approximately 2 seconds).

1 flash, then pause

system locked

2 flashes, then pause

pressure switch stuck closed

3 flashes, then pause

pressure switch stuck open

4 flashes, then pause

open high limit switch

6 flashes, then pause

115 volt AC power reversed

7 flashes, then pause

low flame sense signal

8 flashes, then pause

check ignitor or improper grounding

Continuous flashing

Flame has been sensed when

(no pause)

no flame should be present

(no call for heat)

The LED will also flash once at power-up.

: Power must be disconnected before servicing.