All installations and services must be performed by qualified service personnel.

56

DOES SYSTEM RUN UNTIL

THERMOSTAT IS SATISFIED?

CHECK ALL

WIRING FOR

LOOSE CONNECTIONS.

CHECK FOR SHORT IN WIRE TO

THERMOSTAT AND CORRECT

IF NECESSARY.

DOES BURNER SHUT OFF

WHEN THERMOSTAT IS

SATISFIED?

No

DOES THE CIRCULATING

AIR BLOWER TURN OFF
AFTER THERMOSTAT IS

SATISFIED WITHIN

120 SECONDS?

No

No

Yes

Yes

Yes

Yes

Yes

IS LED LIGHT

ON INTEGRATED

CONTROL FLASHING?

Advertising