54

CHECK WIRING TO INDUCER

AND IF OK, REPLACE

INDUCER ASSEMBLY.

AFTER HOT SURFACE

IGNITOR WARM-UP,

DOES GAS VALVE OPEN?

CHECK WIRING TO

HOT SURFACE IGNITOR

AND IF OK, REPLACE

HOT SURFACE IGNITOR ASSEMBLY.

Yes

Yes

No

Yes

Yes

Yes

Yes

Yes

CHECK WIRING TO GAS

VALVE AND IF OK,

REPLACE GAS VALVE.

DOES THE HOT

SURFACE

IGNITOR ENERGIZE

AND GLOW?

IS THERE LINE VOLTAGE

ACROSS INDUCER POWER

TERMINALS "IND" & "IND N"

AT THE INTEGRATED CONTROL?

CHECK THE INTEGRATED

CONTROL DIAGNOSTIC LED

LAMP. RESET BY INTERRUPTING

POWER TO CONTROL FOR MORE

THAN ONE SECOND. IF LED STAYS

ON CONTINUOUSLY, REPLACE

INTEGRATED CONTROL.

IS THERE VOLTAGE PRESENT

AT THE HOT SURFACE

IGNITOR TERMINALS

"IGN" & "IGN N" AT THE

INTEGRATED CONTROL?

No

No

CHECK THE INTEGRATED CONTROL

DIAGNOSTIC LED LAMP. RESET BY

INTERRUPTING POWER TO CONTROL

FOR MORE THAN ONE SECOND. IF

LED STAYS ON CONTINUOUSLY,

REPLACE INTEGRATED CONTROL.

SAME AS ABOVE.

No

CHECK ACROSS "MV"

TERMINALS ON INTEGRATED

CONTROL FOR 24 VOLTS DURING

THE 4 SECOND FLAME PROVING

PERIOD AFTER IGNITOR WARM-UP.

IS THERE 24VOLTS?

No