53

TURN THERMOSTAT TO CALL FOR HEAT

DOES THERMOSTAT MAKE CONTACT?

IS ROOM TEMPERATURE

BELOW THERMOSTAT

SETTING?

IS ROOM

TEMPERATURE

ABOVE 90 DEGREES F?

TURN T'STAT

SETTING ABOVE

ROOM TEMP.

COOL THE THERMOSTAT

IS THE TRANSFORMER

SUPPLYING 24 VOLTS

TO THE THERMOSTAT?

REPLACE

THERMOSTAT

IS INTERNAL DAMAGE

PRESENT ON THE

TRANSFORMER?

CHECK INPUT

POWER, DOOR

INTERLOCK,

SERVICE SWITCH

AND FUSES.

No

CHECK FOR

CONTINUITY

& PROPER

CONNECTIONS

No

Yes

Yes

REPLACE TRANSFORMER

No

Yes

Yes

No

No

Yes

ARE WIRES CONNECTED

PROPERLY?

No

CORRECT WIRE

CONNECTIONS

No

Yes

Yes

No

Yes

IS THE INDUCER

BLOWER OPERATING?

Yes

IS THERE 24 VOLTS

ACROSS "TH" & "TR"

AT THE INTEGRATED

CONTROL MODEL?

TROUBLESHOOTING GUIDE

THE SYSTEM IS STARTED BY SETTING THE THERMOSTAT TO CALL FOR

HEAT. THE FOLLOWING SHOULD HELP ESTABLISH THE TYPE OF

MALFUNCTION OR DEVIATION FROM THE NORMAL OPERATION.

TO USE THIS DIAGRAM, YOU JUST NEED TO FOLLOW THE INSTRUCTIONS IN THE BOXES.