Thermostat, Variable speed air handler single stage heat pump – Thermo Pride Premiere XT 16 SEER User Manual

Page 11

Advertising
background image

11

FIGURE 12: Thermostat Wiring – Single Stage Heat Pump (with YGVI control) – V/S Air Handler

Single Stage Heat Pump (with YGVI control) – V/S Air Handler

ID MODELS

AV

MV

THERMOSTAT

S1-THSU32P7b

S1-THSU32HP7b

VARIABLE

SPEED

AIR HANDLER

SINGLE STAGE

HEAT PUMP

VARIABLE SPEED

AIR HANDLER

CONTROL

YORKGUARD VI

CONTROL

C

24 - Volt Common

Y1

First Stage

Compressor

R

24 - Volt Hot

G

Fan

Fault

W3

Third Stage Heat

Y2

Second Stage

Compressor

W2

Second Stage Heat

W1/O/B

First Stage Heat

HUM

(only on S1-

THSU32HP7b)

DHUM

(only on S1-

THSU32HP7b)

COM

24 - Volt Common

Y/Y2

Second or Full

Stage Compressor

R

24 - Volt Hot

G

Fan

W1

First Stage Heat

W2

Second Stage Heat

Y1

First

Stage Compressor

O

Reversing Valve

Energized in Cool

X/L

Malfunction Light

HUM

Humidity Switch

Open on Humidity Rise

HUM OUT

(24 VAC out)

Humidifier

EAC

(24 VAC out)

Electronic Air Cleaner

Jumper 1 must be set

to “HEAT PUMP”

Jumper 2 must be set

to “O”

Jumper 3 must be set

to “ELEC”

Setup Step 24 “NUMBER

Of Compressor Stages”

must be set “1”

24VAC Humidifier

(Optional)

24VAC

Electrontic Air Cleaner

(Optional)

Part Number:

SAP

536805

Move the HUM STAT

jumper to “YES”

if humidistat is to be

used.

Refer to AH

documentation

for W1 and W2 electric

heat staging options.

Part Numbers:

SAP

524851
500644

Change FFuel jumper

on the heat pump control

to “OFF”

BS

Bonnet Sensor

BSG

Bonnet Sensor

W

Auxiliary Heat

Y2

Second Stage

Compressor

X/L

Malfunction Light

O

Reversing Valve

Energized in Cool

W1 OUT

First Stage Heat

W2 OUT

Second Stage Heat

Y2 OUT

Second Stage

Compressor

R

24 - Volt Hot

Y1

Single Stage

Compressor

C

24 - Volt Common

1

2

1

2