Thermo Pride Premiere XT 16 SEER User Manual

Page 17

Advertising
background image

17

FIGURE 18: Thermostat Wiring – Two-Stage Heat Pumps - Variable Speed Air Handler

HP 27C

Two Stage Heat Pump – Variable Speed Air Handler (With Hot Heat Pump Operation)

O

Reversing Valve

Energized in Cool

C

24 – Volt Common

R

24 – Volt Hot

W1 OUT

First Stage Heat

W2 OUT

Second Stage Heat

Y2 OUT

Second Stage Compressor

Y1

Single Stage Compressor

X/L

Malfunction Light

Y2

Second Stage Compressor

W

Auxiliary Heat

BS

Bonnet Sensor

BSG

Bonnet Sensor

TWO STAGE

HEAT PUMP

C

24 – Volt Common

R

24 – Volt Hot

Y1

First Stage Compressor

O

Reversing Valve

Energized in Cool

L

Malfunction Light

Y2

Second Stage Compressor

G

Fan

*DN22H00124

*DP22U70124

THERMOSTAT

E/W1

First Stage Aux. Heat

W2

Second Stage Aux. Heat

Step 1 of Thermostat

Installer/Configuration

Menu must be set to “HP2”

Selection of GAS/ELEC

switch on thermostat

not necessary

C

24 – Volt Common

Y

First Stage Compressor

O/B

Reversing Valve

L

Malfunction Light

Y2

Second Stage Compressor

G

Fan

*PP32U70124

THERMOSTAT

E

Emergency Heat

R

24 – Volt Hot

(Heat XFMR)

RC

24 – Volt Hot
(Cool XFMR)

Thermostat Installer Setup

0170-System Type-

must be set to 12

3 Heat/2 Heat Pump

Thermostat Installer Setup

0190-Changeover Valve-

must be set to 0

O/B terminal

Energized in Cooling

Thermostat Installer Setup

0200-Backup Heat Source-

must be set to 0

Heat Pump Backup Heat

Source is Electric

AUX

Auxiliary Heat

1

24VAC Humidifier

(Optional)

Part Numbers:

SAP = Legacy

159481 = 031-09157

2

COM

24 – Volt Common

R

24 – Volt Hot

W1

First Stage Aux. Heat

W2

Second Stage Aux. Heat

Y1

Single Stage Compressor

Y/Y2

Second or Full

Stage Compressor

O

Reversing Valve

Energized in Cool

X/L

Malfunction Light

HUM

Dehumidification-

Open on Humidity Rise

VARIABLE SPEED

AIR HANDLER CONTROL

G

Fan

Move the MODE

jumper to “HP”

Move HUM STAT

jumper to “YES”

if humidistat is to be used.

VARIABLE SPEED

AIR HANDLER

2

Part Numbers:

SAP = Legacy

126768 = 031-09137

18395 = 031-01996
340512 = 031-09178

1

AV

ID MODELS

SV

MV

YZE

YZH

H*5

YORKGUARD VI

CONTROL

H*8

24VAC

Electronic Air Cleaner

(Optional)

EAC(24 VAC out)

Electronic Air Cleaner

External Humidistat

(Optional)

Open on Humidity Rise

HUM OUT

(24 VAC out)

Refer to AH documentation

for W1 and W2 electric

heat staging options.

Second stage auxiliary

heat will be controlled by

the thermostat, not the

heat pump control when

wired as shown.

OD MODELS

Change Hot Heat Pump

jumper on the heat pump

control to “ON”

3

Part Number:

S1-2HU16700124

3