FIGURE 14: Thermostat Wiring – Single Stage Heat Pump (with YGVI control) – V/S Air Handler

Single Stage Heat Pump (with YGVI control) – V/S Air Handler

ID MODELS

AV

MV

S1-THSU21P1b

THERMOSTAT

VARIABLE

SPEED

AIR HANDLER

SINGLE STAGE

HEAT PUMP

VARIABLE SPEED

AIR HANDLER

CONTROL

YORKGUARD VI

CONTROL

C

24 - Volt Common

Y1

First Stage

Compressor

R

24 - Volt Hot

G

Fan

W2

Second Stage Heat

COM

24 - Volt Common

Y/Y2

Second or Full

Stage Compressor

R

24 - Volt Hot

G

Fan

W1

First Stage Heat

W2

Second Stage Heat

Y1

First

Stage Compressor

O

Reversing Valve

Energized in Cool

X/L

Malfunction Light

HUM

Humidity Switch

Open on Humidity Rise

HUM OUT

(24 VAC out)

Humidifier

EAC

(24 VAC out)

Electronic Air Cleaner

24VAC Humidifier

(Optional)

24VAC

Electrontic Air Cleaner

(Optional)

Move the HUM STAT

jumper to “YES”

if humidistat is to be

used.

Refer to AH

documentation

for W1 and W2 electric

heat staging options.

Jumper 1 must be set

to “HEAT PUMP”

Jumper 2 must be set

to “O”

Jumper 3 must be set

to “ELEC”

Change FFuel jumper

on the heat pump control

to “OFF”

External Humidistat

(Optional)

Open on Humidity Rise

Y2

Second Stage

Compressor

X/L

Malfunction Light

O

Reversing Valve

Energized in Cool

W1 OUT

First Stage Heat

Y2 OUT

Second Stage

Compressor

R

24 - Volt Hot

C

24 - Volt Common

BS

Bonnet Sensor

BSG

Bonnet Sensor

W

Auxiliary Heat

Y1

Single Stage

Compressor

W2 OUT

Second Stage Heat

1

2

2

3

1

3

Part Number:

SAP

536805

Part Numbers:

SAP

524851
500644

Part Number:

S1-2HU16700124