Thermo Pride Premiere XT 16 SEER User Manual

Page 14

Advertising
background image

14

FIGURE 15: Thermostat Wiring – Two-Stage Heat Pumps - Two-Stage Variable Speed Furnaces

HP 24A

Two Stage Heat Pump – Two Stage Variable Speed Furnace (With Hot Heat Pump Operation)

O

Reversing Valve

Energized in Cool

C

24 – Volt Common

R

24 – Volt Hot

W1 OUT

First Stage Heat

W2 OUT

Second Stage Heat

Y2 OUT

Second Stage Compressor

Y1

Single Stage Compressor

X/L

Malfunction Light

Y2

Second Stage Compressor

W

Auxiliary Heat

BS

Bonnet Sensor

BSG

Bonnet Sensor

TWO STAGE

HEAT PUMP

Bonnet Sensor

(Optional)

C

24 – Volt Common

Y1

First Stage Compressor

L

Malfunction Light

Y2

Second Stage Compressor

G

Fan

*PP32U71124
*PP32U72124

THERMOSTAT

R

24 – Volt Hot

E/W1

First Stage Aux. Heat

W2

Second Stage Aux. Heat

DHM

Dehumidistat

HM

Humidistat

O

Reversing Valve

Energized in Cool

Change FFuel jumper

on the heat pump control

to “ON”

Part Numbers:

SAP = Legacy

126768 = 031-09137

18395 = 031-01996
340512 = 031-09178

1

1

Part Numbers:

SAP = Legacy

265904 = 031-09169

2

C

24 – Volt Common

R

24 – Volt Hot

Y1

Single Stage Compressor

TWO STAGE

VARIABLE SPEED

FURNACE CONTROL

G

Fan

TWO STAGE

VARIABLE SPEED

FURNACE

W/W1

First Stage Heat

Y/Y2

Second or Full

Stage Compressor

W2

Second Stage Heat

O

Reversing Valve

X/L

Malfunction Light

DHUM

Dehumidification

2

Move HEAT PUMP

jumper to “YES”

Move DHUM

jumper to “YES”

if humidistat is to be used.

PV(8/9)

ID MODELS

(F/L)*(8/9)V

YORKGUARD VI

CONTROL

(G/L)(8/9)V

YZE

OD MODELS

YZH

H*5

H*8

24VAC Humidifier

(Optional)

Step 1 of the Thermostat

Installer Table must be

set to Heat Pump

E2/P Switch must be in the

E2 position

Step 2 of the Thermostat

Installer Table must be

set to 2

Step 5 of Thermostat User

Configuration Menu must

be set to “ON” for

Dehumidification

Change Hot Heat Pump

jumper on the heat pump

control to “ON”