11

XL-PH10412UM-en-US Rev A · 2011-10-28 · Amendments and errors reserved. © SAF-HOLLAND, Inc.

Mounting Instructions

Figure 14

Figure 15

Figure 13

Figure 12

5. Clean the interior of the housing then

wipe dry with a clean rag. Inspect
for cracks or damage. If cracked or
damaged obtain and install a new
housing (XA-749 or XA-749-1) before
proceeding. See Parts List, page 5.

6. Check mounting bolt torque:

a. Thru-bolt to the mounting structure:

Tighten four (4) 7/8" diameter Grade 8

bolts, ASTM Grade C lock nuts, and
hardened washers. Torque to 400 ft.-lbs.
/tN (Figure 12).

b. Direct bolt to drilled and tapped

mounting structure:

Tighten four (4) 7/8" diameter Grade 8

bolts and torque to 400 ft.-lbs.
/tN (Figure 13).

1SFQBSFUIFOFX1)4/

TVCBTTFNCMZ

7. Remove and retain the cotter pin

(XB-781-1) (Figure 14).

8. Remove and retain the castellated

nut (XB-780-1) (Figure 15).

TOP VIEW

#0-54

-0$,/654
"/%8"4)&34

#0-54

$055&3
1*/

$"45&--"5&%/65