Edirol V-44SW E1 User Manual

Page 61

Advertising
background image

61

REMOTE Command Reference

OUT OUTPUT FORMAT Button Select

stxOUT:a;

a

: 0–2 (0: 1080i, 1: 720p, 2: RGB)

This selects the OUTPUT FORMAT button, changing the format of
the video output.

ACK is returned by the V-44SW upon proper reception of the
command.

FAD OUTPUT FADE Operation

stxFAD:a;

a

: OUTPUT FADE status

(0–255, 0: FADE MAX, 255: VIDEO MAX)

This sets the concentration during fadeouts of the video output
from the HD/RGB OUT PGM connectors.

ACK is returned by the V-44SW upon proper reception of the
command.

RST V-44SW Reset

stxRST;

This resets the V-44SW’s panel status, with the Factory Presets
called up.

ACK is returned by the V-44SW upon proper reception of the
command.

VER Version Information Request

stxVER;

Transmit this when you want to check the V-44SW’s version. The
version information is returned.

* For more details on version information, refer to “VER Version

Information” on this page.

ACS Active Sensing Request

stxACS;

Transmit this when you want to check the V-440HD’s status.

ACK is returned when no operation is being performed by the
V-44SW.

DAT Data Transmission

stxDAT:aaaa,bbbb;

aaaa

: Address (aaaa, bbbb are in hexadecimal)

bbbb

: Data

This overwrites the data at the specified address.

After the required data is transmitted, FFFF,xxxx; is transmitted as
the final string of the command, and the data is written (xxxx
represents the data version).

ACK is returned when no operation is being performed by the
V-44SW.

* The “Serial Data Tool” application are available from the Roland

Systems Group website. For more detailed information, refer to
the column “Serial Data Transmissions” on this page.

XON Flow Control

XON

XOFF Flow Control

XOFF

In the following, stx (02H), ACK (06H), and Xon (11H) / Xoff (13H) are
control codes.

ACK Acknowledgment of Proper Reception

ACK

This is transmitted when a command is received properly.

ERR Error Information

stxERR:a;

a

: 0 (syntax error)

Error in the syntax of the received command.

2 (busy error)
V-44SW busy, command cannot be processed.

5 (out of range error)
Number in received command is out of range.

20 (some thing error)
Other error. Transmitted when the V-44SW is unable to process
the command properly

VER Version Information

stxVER: “a”, “b”, “c”;

a

: Model Name (V-44SW)

b

: Version

c

: Rese

rved

This is transmitted when the V-440SW receives a VR command
version. The version information is transmitted as an ASCII
character string.

DAT Data Transmission

stxDAT:aaaa,bbbb;

aaaa

: Address (aaaa, bbbb are in hexadecimal)

bbbb

: Data

The data is transmitted to the specified address.

After the required data is transmitted, FFFF,xxxx; is transmitted as
the final string of the command, and the data is written (xxxx
represents the data version).

* The “Serial Data Tool” application are available from the Roland

Systems Group website. For more detailed information, refer to
the column “Serial Data Transmissions” on this page.

XON Flow Control

XON

XOFF Flow Control

XOFF

Commands Transmitted from the
V-44SW to External Devices

Serial Data Transmissions

The following data and application have been made available by
the Roland system Group. You may download and use these
materials.

http://rolandsystemsgroup.net

“Serial Data Tool” V-440HD settings backup and restore tool
(for Windows XP only)

The “Serial Data Tool” for the V-440HD may also be used with
the V-44SW.

V-44SW_e.book 61 ページ 2006年10月23日 月曜日 午後3時25分