Important notes – Edirol V-44SW E1 User Manual

Page 8

Advertising
background image

8

IMPORTANT NOTES

In addition to the items listed under “IMPORTANT SAFETY INSTRUCTIONS” and “USING THE UNIT SAFELY” on pages 2
and 6–7, please read and observe the following:

301

Do not connect this unit to same electrical outlet that is
being used by an electrical appliance that is controlled by
an inverter (such as a refrigerator, washing machine,
microwave oven, or air conditioner), or that contains a
motor. Depending on the way in which the electrical
appliance is used, power supply noise may cause this unit
to malfunction or may produce audible noise. If it is not
practical to use a separate electrical outlet, connect a
power supply noise filter between this unit and the
electrical outlet.

307(changed)

Before connecting this unit to other devices, turn off the
power to all units. This will help prevent malfunctions and/
or damage to video monitors or other devices.

308

Although the LEDs are switched off when the POWER
switch is switched off, this does not mean that the unit has
been completely disconnected from the source of power. If
you need to turn off the power completely, first turn off the
POWER switch, then unplug the power cord from the
power outlet. For this reason, the outlet into which you
choose to connect the power cord’s plug should be one
that is within easy reach and readily accessible.

added

To ensure long service life, be sure to shut off the power
whenever the unit is not being used and limit continuous
operation as much as possible.

352a

This device may interfere with radio and television
reception. Do not use this device in the vicinity of such
receivers.

352b

Noise may be produced if wireless communications
devices, such as cell phones, are operated in the vicinity
of this unit. Such noise could occur when receiving or initi-
ating a call, or while conversing. Should you experience
such problems, you should relocate such wireless devices
so they are at a greater distance from this unit, or switch
them off.

355b

When moved from one location to another where the
temperature and/or humidity is very different, water
droplets (condensation) may form inside the unit. Damage
or malfunction may result if you attempt to use the unit in
this condition. Therefore, before using the unit, you must
allow it to stand for several hours, until the condensation
has completely evaporated.

360

Depending on the material and temperature of the surface
on which you place the unit, its rubber feet may discolor or
mar the surface.
You can place a piece of felt or cloth under the rubber feet
to prevent this from happening. If you do so, please make
sure that the unit will not slip or move accidentally.

401a

For everyday cleaning wipe the unit with a soft, dry cloth
or one that has been slightly dampened with water. To
remove stubborn dirt, use a cloth impregnated with a mild,
non-abrasive detergent. Afterwards, be sure to wipe the
unit thoroughly with a soft, dry cloth.

402

Never use benzine, thinners, alcohol or solvents of any
kind, to avoid the possibility of discoloration and/or defor-
mation.

452

Please be aware that all data contained in the unit’s
memory may be lost when the unit is sent for repairs.
Important data should always be backed up in another
MIDI device (e.g., a sequencer), or written down on paper
(when possiblrepairs, due care is taken to avoid the loss of
data. However, in certain cases (such as when circuitry
related to memory itself is out of order), we regret that it
may not be possible to restore the data, and Roland
assumes no liability concerning such loss of data.

551(changed)

Damage or breakdown of the unit or mistakes in operation
may result in the loss of data stored in memory. To avoid
problems in the event of the loss of important data, write
down the settings or follow the instructions to save the
data to your computer (p. 49) or other external device.

552

Unfortunately, it may be impossible to restore the contents
of data that was stored in another MIDI device (e.g., a
sequencer) once it has been lost. Roland Corporation
assumes no liability concerning such loss of data.

553

Use a reasonable amount of care when using the unit’s
buttons, sliders, or other controls; and when using its jacks
and connectors. Rough handling can lead to malfunctions.

556

When connecting / disconnecting all cables, grasp the
connector itself—never pull on the cable. This way you will
avoid causing shorts, or damage to the cable’s internal
elements.

557

A small amount of heat will radiate from the unit during
normal operation.

559a

When you need to transport the unit, package it in the box
(including padding) that it came in, if possible. Otherwise,
you will need to use equivalent packaging materials.

added

This device allows you to switch images or turn video
effects on/off at high speed. For some people, viewing
such images can cause headache, nausea, or other
discomfort. Do not use this device to create video that
might cause these types of health problems. Roland
Corporation will accept no responsibility for any such
health problems that may occur in yourself or in viewers.

Power Supply

Placement

* Microsoft and Windows are registered trademarks of

Microsoft Corporation.

Maintenance

Repairs and Data

Additional Precautions

V-44SW_e.book 8 ページ 2006年10月23日 月曜日 午後3時25分

Advertising