5diagnostics and troubleshooting – ProSoft Technology ILX800-SMSG User Manual

Page 31

Advertising
background image

ILX800-SMSG ♦ Micro800 Platform

Contents

SMS Text Plug-in Module for GSM Networks

User Manual

ProSoft Technology, Inc.

Page 31 of 41

June 18, 2014

5

Diagnostics and Troubleshooting

In This Chapter

LED Status Indicator ..............................................................................31

Troubleshooting .....................................................................................31

Status Data ............................................................................................32

5.1

LED Status Indicator

Color

Status

Indication

Green

OFF

The plug-in module is not receiving adequate
power or is not securely plugged into the slot.

BLINKING RAPIDLY
(~once per second)

The plug-in module is powered on and is
attempting to establish a connection with the
service carrier.

BLINKING SLOWLY
(~once every two
seconds)

The plug-in module is powered on and
communicating on the cellular network.

5.2

Troubleshooting

Use the following troubleshooting steps if you encounter problems when the plug-in module
is powered up. If these steps do not resolve your problem, please contact ProSoft
Technology Technical Support.

Problem Description

Steps to take

The green LED is OFF

This indicates that the module is not powered on. Verify that

The module is securely connected in its slot

The controller is powered on

The green LED
continues to blink
rapidly

This indicates that the module has not yet established a connection with
the service carrier.

Wait a couple of minutes to see if a connection is established

Verify that a valid SIM card is properly installed in the module's SIM
card holder

Verify that an external antenna is securely connected to the antenna
connector on the module

Advertising