popular. However, crossover filter types

must be carefully selected to match the

acoustic response of the specific loudspeaker

system. Please consult the manufacturer of

the loudspeaker system for recommended

crossover frequencies and filter types.

FIR Filter

(output only)

A FIR (finite impulse response) filter is typically

used when a speaker manufacturer develops

and provides a proprietary FIR coefficient

file that corresponds directly to their own

loudspeaker or speaker cabinet, addressing

frequency and phase issues based on their own

measurements and formulations.
Plugging in a FIR filter DSP block then clicking

on it will prompt the user for a *.fir or *.csv

text file, which is then loaded and applied to

the output DSP. The two file types will have

identical coefficient code, however the *.fir file

may add comments (designated by a semi-

colon) or a key=value pair definition such as

sample rate. Either file type will work.

*.fir file example:

; comments section
sampleRate = 48000
+0.0000042920
+0.0000030236
-0.0000040482

*.csv file example:

+0.0000042920
+0.0000030236
-0.0000040482
The software does not offer the ability to view

or edit the EQ curve as produced by a FIR filter.

FIR filters on this device can have from 2 up to

512 taps.