Cooling, Network, Browser & resolution – Ashly mXa-1502 12-Channel 4-Zone DSP Mixer-Amplifier User Manual

Page 6: Front panel features, Mounting holes, Cooling vents, Device reset switch, Channel leds, Select buttons, 3front panel features

Advertising
background image

2.3

Cooling

Air vents on the amplifier front and side

panels must have access to free flowing room

temperature air. Cool air is drawn in through

the side and blown out the front. It is not

necessary to leave empty rack spaces above

or below the amplifier. See the BTU/hr table in

the specifications section for thermal output

characteristics.

2.4

Network

A standard 100MHz or faster network is required.

Connect the mXa-1502 Ethernet jack to a net-

work switch or router, or directly to a computer.

Once a successful Ethernet connection has

been made, a solid green LED (Link) lights up on

the RJ-45 Ethernet port. If there is no green LED

showing, there is either a problem with the cable

or network connection which must be addressed

before proceeding further. All RJ-45 Ethernet

ports flash green when active, so backtrack

through any other cables, routers, or switches

to find the problem. The flashing yellow LED

(Data) indicates that data is flowing to or from the

device. See

section 5

for detailed instructions on

mXa-1502 network discovery.

2.5

Browser and Resolution

Supported browsers include Chrome, Edge

(Win10 recommended), and Safari. The

software requires a minimum screen resolution

of 1024 x 768. For use with a tablet, a minimum

screen size of 10" is recommended.

3

Front Panel Features

3.1

Mounting Holes

For rack mounting. Always use all four screws.

3.2

Cooling Vents

Cool air enters the sides and is vented out

through the front.

3.3

Device Reset Switch

There are two levels of device reset, Admin reset

or Factory Default reset, determined by how long

you press and hold in this recessed switch during

a

cold-boot

power-up.

A cold-boot power-up means that AC power is

removed before initiating reset.
To initiate reset, first press and hold in the reset

switch using a pencil-tip or paperclip, then

insert the power cord or turn on the power

outlet the device is plugged into. During the

reset process, all channel LEDs will light up from

bottom to top, followed by the four status LEDs.

To cancel reset before it completes, release the

reset switch before the green Signal LEDs turn on.

1) Admin reset

changes the Admin User ID

password back to <secret>, but preserves

all other user IDs/passwords, presets, and

settings. Use this level if you forgot the admin

password.

To perform an Admin reset,

release the reset

switch after the green signal LEDs turn on,

but before the red Clip/Mute LEDs turn on.

2) Factory Default reset

deletes all User

IDs and passwords, deletes all presets, and

restores all settings to factory default. Use this

level to completely scrub the device clean of

any previous programming.

To perform a Factory Default reset,

release

the reset switch after the red Clip/Mute LEDs

turn on.

3.4

Channel LEDs

The red Clip/Mute LEDs flash when output

voltage is 0.5V below the output power supply

voltage, or when an input signal or DSP section

is clipped. This LED also lights when the output

channel is muted.
The green signal LEDs light when the output

voltage reaches -18dBu below rated output.
The green current LEDs confirm that amplifier

output is being delivered to a speaker load.
The yellow temp LEDs indicate that the

amplifier channel has reached an excessively

high operating temperature and will gradually

attenuate the signal to compensate. If unable

to sufficiently cool the channel, the amplifier

will put itself into protect mode.

3.5

Select Buttons

The four select buttons are initially

unassigned. They can be programmed in

software to perform preset/sub-preset

recall or source select. To program select

buttons in AquaControl

software, go to

[

Settings>Panels>Front Button Settings

].

6

mXa-1502 • Operating Manual

Advertising