Table 5, Table 310-16, national electrical code (reprint), Table 5 of this manual, a – Emerson Series 610 User Manual

Page 32

Advertising
background image

Wiring Inspection

28

Table 5

Table 310-16, National Electrical Code (Reprint)

Allowable Ampacities of Insulated Conductors Rated 0-2000 Volts, 60° to 90°C (140° to 194°F)

1

Not More Than Three Conductors in Raceway or Cable or Earth (Directly Buried), Based on Ambient Temperature of 30°C (86°F)

SIZE

TEMPERATURE RATING OF CONDUCTOR. SEE TABLE 310-13.

SIZE

AWG

kcmil

60°C

(140°F)

75

°

C

(167

°

F)

90

°

C

(194

°

F)

60

°

C

(140

°F

)

75

°

C

(167

°

F)

90

°

C

(194

°

F)

AWG

kcmil

TYPES

TW=

UF=

TYPES

FEPW=,

RH, RHW=,

THHW=,

THW=,

THWN=,

XHHW=,

USE=, ZW=

TYPES

TBS, SA,

SIS, FEP=

FEPB=, MI,

RHH= RHW-2

THHN=, THHW=,

THW-2, THWN-2,

USE-2, XHH,

XHHW=

XHHW-2, ZW-2

TYPES

TW=

UF=

TYPES

RH=, RHW=,

THHW=,

THW=,

THWN=,

XHHW=,

USE=

TYPES

TBS,

SA, SIS,

THHN=,

THHW=,

THW-2, THWN-2,

RHH==, RHW-2,

USE-2,

XHH, XHHW=,

XHHW-2, ZW-2

COPPER

ALUMINUM OR COPPER-CLAD ALUMINUM

18

16

14*

12*

10*

8

.......

.......

20

25

30

40

.......

.......

20

25

35

50

14

18

25

30

40

55

.......

.......

.......

20

25

30

.......

.......

.......

20

30

40

.......

.......

.......

25

35

45

.......

.......

.......

12*

10*

8*

6

4

3

2

1

55

70

85

95

110

65

85

100

115

130

75

95

110

130

150

40

55

65

75

85

50

65

75

90

100

60

75

85

100

115

6

4

3

2

1

1/0

2/0

3/0

4/0

125

145

165

195

150

175

200

230

170

195

225

260

100

115

130

150

120

135

155

180

135

150

175

205

1/0

2/0

3/0

4/0

250

300

350

400

500

215

240

260

280

320

255

285

310

335

380

290

320

350

380

430

170

190

210

225

260

205

230

250

270

310

230

255

280

305

350

250

300

350

400

500

600

700

750

800

900

355

385

400

410

435

420

460

475

490

520

475

520

535

555

585

285

310

320

330

355

340

375

385

395

425

385

420

435

450

480

600

700

750

800

900

1000

1250

1500

1750

2000

455

495

520

545

560

545

590

625

650

665

615

665

705

735

750

375

405

435

455

470

445

485

520

545

560

500

545

585

615

630

1000

1250

1500

1750

2000

CORRECTION FACTORS

Ambient

Temp °C

For ambient temperatures other than 30°C (86°F), multiply the allowable ampacities

shown above by the appropriate factor shown below.

Ambient

Temp °F

21-25

26-30

31-35

36-40

41-45

46-50

51-55

56-60

61-70

71-80

1.08

1.00

.91

.82

.71

.58

.41

.......

.......

.......

1.05

1.00

.94

.88

.82

.75

.67

.58

.33

.......

1.04

1.00

.96

.91

.87

.82

.76

.71

.58

.41

1.08

1.00

.91

.82

.71

.58

.41

.......

.......

.......

1.05

1.00

.94

.88

.82

.75

.67

.58

.33

.......

1.04

1.00

.96

.91

.87

.82

.76

.71

.58

.41

70-77

78-86

87-95

96-104

105-113

114-122

123-131

132-140

141-158

159-176

*

Unless otherwise specifically permitted in Section 240-3 of this Code, the overcurrent protection for conductor types marked with an
asterisk (*) shall not exceed 15 amperes for No. 14, 20 amperes for No. 12, and 30 amperes for No. 10 copper; or 15 amperes for No. 12
and 25 amperes for No. 10 aluminum and copper-clad aluminum after any correction factors for ambient temperature and number of
conductors have been applied.

1. Reprinted with permission from NEC 1999, NFPA 70, the National Electrical Code

®

, Copyright 1998,

National Fire Protection Association, Quincy, MA 02269. This reprinted material is not the complete and

official position of the National Fire Protection Association, on the referenced subject which is

represented only by the standard in its entirety.

Advertising