www.enviromaster.com

WLCA/WLHA High Wall Evaporator

4

itEms for ConsidErAtion

Determine the best location for mount-

ing the unit for room air circulation.

Locate outdoor and indoor units as

close together as possible.

Determine how power wire (high and

low voltage) condensate drainage,

and refrigerant piping may be run to

and from the unit.

WLCA/WLHA - Ensure that intercon-

nect tubing is within the maximum

allowable length of 100’ including a

maximum 35’ lift.

To ensure serviceability and proper

air distribution, the unit should be

positioned as close as possible to the

center (left-to-right) of the wall. Minimum

distance from the ceiling is stated on the

template provided with the unit packag-

ing. The cabinet left and right end caps

must be accessible for removal without
obstruction.

(See below)

Modular design – reduces parts

required for control package. Deco

panel, relay board, ribbon cables and

microprocessor are combined into one

package.

Integral condensate pump safety-

switch connection

where-by the mi-

croprocessor monitors the condensate

pump safety switch and displays an

error code when a fault occurs. (Applies

only with optional condensate pump)

CEC

(California Energy Commission)

compliant

• Condensate drain pan over flow

protection

Cabinet Features:

• Durable ABS plastic cabinet with a

galvanized steel sub-chassis.

• Easily accessible, washable, reusable,

nylon mesh filter.

• Horizontal discharge louver, construct-

ed of high temperature ABS plastic,
that can be set to oscillate, or can be

parked in six pre-set positions.

• Manually adjustable vertical discharge fins.

• Easy access to pipe chase area from

cabinet bottom allows piping connec-

tions and condensate pump installation
with the unit mounted on the wall.

• Easily removable end-cap for access to

control area for installation and service.

• Condensate drain pan constructed of

galvanized steel (G90U), with anti-cor-

rosion coating.

• Modular snap-in, 7-day programmable

control with large backlit LCD display,

a “Change filter” display feature and

selectable Fahrenheit (Fº), or Celsius

(Cº) temperature scale.

WLCA/WLHA ControLs And ComponEnts

Continued

optionAL EqUipmEnt

• Condensate pump (field installed only)

• 24V remote wall thermostat

• Electric heat with automatic reset high

temperature cutout and redundant

high temperature fuse link (when heat

option is selected)

• Hand held infrared controller.

instALLEr sUppLiEd itEms

• Low voltage wiring (18 awg required)

• High voltage power supply wiring

• Mounting screws and fasteners

• Condensate piping

• Refrigerant piping (if not supplied)

• Refrigerant (for interconnect charge)

IMPORTANT:

Check equipment for damage

prior to installation, if damaged contact the

wholesale distributer.

CEiLinG

W

ALL

W

ALL

4” Minimum

10”

Minimum

6”

Min.

notE:

Unit mounted controls are fully func-

tional without the remote.

NOTE:

If the control is configured for unit

mount control do NOT connect a wall ther-

mostat to the unit.