Maintenance and service – Enviro DV36 User Manual

Page 13

Advertising
background image

13

Maintenance And Service

8. Reinstall the burner, brick panels, log set, embers, and glass door.

Also refer to S

ECONDARY

I

NSTALLATION

- I

NSTALLING

L

OG

S

ET

AND

E

MBERS

in your Owner’s Manual. When re-installing the burner, ensure that

the burner to pilot hood relationship is similar to what is shown in

Figure 14. On some units you will need to pay special attention when

installing the burner that the venturi adjustment rod is properly

installed into the venturi adjustment piece welded to the burner

venturi tube

Figure 13: O-ring on valve screw.

9. Reconnect the main gas line if it was disconnected and open the shut-off valve at the gas line to the

unit.

10. Use a small brush to apply a warm soapy water solution to all gas connections (use a half dish soap

and half warm water). If a gas leak is present, bubbling will occur. Gas leaks can be repaired by

using an approved pipe thread sealant or approved Teflon tape. NEVER USE AN OPEN FLAME WHEN

TESTING FOR LEAKS.

11. Reconnect the electrical power to the unit.
12. Relight the main burner in both the “HI” and “LO” positions to verify proper burner ignition and

operation and proper flame appearance. Also refer to S

ECONDARY

I

NSTALLATION

- I

NSTALLING

L

OG

S

ET

AND

E

MBERS

in your Owner’s Manual for a flame appearance picture.

13. MAKE SURE that the conversion label is installed on or close to the rating label to signify that the

unit has been converted to a different fuel type.

Figure 14. Ignitor assembly

beside the burner.

g) Re-attach the black protection

cap that was removed in step

a (Figure 10).