Initial installation – Enviro DV36 User Manual

Page 24

Advertising
background image

24

Initial Installation

QUALIFIED INSTALLERS ONLY

Step 3. To install the Round

Support Box/Wall Thimble

in a flat ceiling, cut a 10

inch (25.4 cm) square hole

in the ceiling, centered in

the hole drilled in Step 2.

Frame the hole as shown

in Figure 29.

Step 4. Assemble the desired

lengths of black pipe

and elbows necessary to

reach from the appliance

adapter up through the

Round

Support

Box.

Insure that all pipe and

elbow connections are

in their fully twist-locked

position.

Figure 34. Vertical Vent Termination

NOTE: For Simpson Duravent only, place a bead of Mil-Pac or Rutland No 78 Stove and Gasket Cement

on the outer edge of the inner exhaust pipe (non-flared end). Push the pipe sections together, then twist

about 1⁄4 turn, making sure the two sections are fully locked. Wrap all seams with foil ducting tape.
Step 4. With the hole now framed, the wall thimble installed, and the pipe extending into the wall,

proceed to the outside. Attach the termination to the pipe using RTV and Mil-Pac or Rutland No

78 Stove and Gasket Cement to seal joints. The vent pipe must extend into the vent cap at least

11⁄4 inches (3.2 cm). Secure the connection between the vent cap and the pipe by attaching the

two (2) sheet metal straps, which extend from the vent cap assembly to the outer wall of the

vent pipe. Bend any remaining portion of the strap back towards the vent cap. Security Secure

Vent uses a twist lock cap.

Step 5. Position the horizontal vent termination in the center of the 10 inches (25.4 cm) square hole

and attach to the exterior wall with the four screws provided. The arrow on the vent termination

should be pointing up. Run a bead of non-hardening mastic around the edges of the vent

cap, to make a seal with the wall. Ensure the proper clearances to combustibles have been

maintained.

V

ERTICAL

T

ERMINATION

:

Step 1. Check the instructions for required clearances (air spaces) to combustibles when passing

through ceilings, walls, roofs, enclosures, attic rafters, or other nearby combustible surfaces.

Do not pack air spaces with insulation.

Step 2. Set the gas appliance in the desired location. Drop a plumb bob down from the ceiling to

the position of the appliance flue exit, and mark the location where the vent will penetrate

the ceiling. Drill a small hole at this point. Next, drop a plumb bob from the roof to the hole

previously drilled in the ceiling, mark the spot where the vent will penetrate the roof. Determine

if ceiling joists, roof rafters, or other framing will obstruct the venting system. You may wish to

relocate the appliance, or to offset, to avoid cutting load bearing members.

Vertical

Termination

Storm Collar

Flashing

Roofing nails

Elbow Strap