Operating instructions – Enviro DV36 User Manual

Page 8

Advertising
background image

8

Operating Instructions

For Your Safety, Read Safety Precautions And

Lighting Instructions Before Operating

E) Turn on all electrical power to the unit.

NOTE: Check that all burner holes are lit.
TO TURN GAS FIREPLACE OFF:
Flip switch to OFF to turn off burners only.
If the fireplace is to be turned off for the season,

or for servicing, turn the gas shut off valve to

OFF. DO NOT FORCE IT. If the unit is going to

be serviced, turn off the electrical power to the

unit as well.
NOTE: When the unit is turned on for the first time, it should be turned onto high, with the fan OFF,

for the first two to four hours. This will cure the paint, logs, gasket material, and other products used

in the manufacturing process. It is advised that a door or window be opened as the unit will start to

smoke, which can irritate some people. After the unit has gone through the first burn, turn the unit OFF,

including the pilot, and let the unit get completely cold. Then remove the glass and clean it with a good

gas fireplace glass cleaner, available at your local Enviro dealer. See “M

AINTENANCE

A

ND

S

ERVICE

; G

LASS

D

OOR

R

EMOVAL

” and “M

AINTENANCE

A

ND

S

ERVICE

; C

LEANING

T

HE

G

LASS

.”

B

LOWER

SPEED

(O

PTIONAL

):

��

���

��

Figure 5. Control Panel

Figure 6. Fan Control

����� �������

������

����

���

�������

B

URNER

L

IGHTING

:

A) Make sure the pilot is lit.

B) Turn gas control knob COUNTER CLOCKWISE to ON.

C) Flip the burner switch to ON.

D) Turn HI/LO knob to the desired flame height.

The blower will come on only when the fireplace is up to temperature

(approximately 20 minutes). The speed of the fan can be changed by turning the

fan control knob. To turn the blower off, turn the knob COUNTER CLOCKWISE

until it “clicks” off (Figure 6).
It is advisable not to operate the blower below

1

/

3

speed as it puts a strain on

the windings of the blower and running the blower at lower speeds could also

cause premature fan failure.

N

ORMAL

S

OUNDS

D

URING

O

PERATION

:

Table 1: Normal Sounds

Component

Sound & Reason

DV36 & Fascia

Creaking when heating up or cooling down.

Burner

Light pop or poof when turned off; this is more common with LP units.

Temperature Sensor

Clinking when it senses to turn the blower on or off.

Pilot Flame

Quiet whisper while the pilot flame in on.

Blower / Fan

Air movement that increase and decreases with the speed of the blower. The

blower is pushing the heat from the fireplace into the room.

Gas Control Valve

Dull click when turning on or off, this is the valve opening and closing.