Initial installation – Enviro DV36 User Manual

Page 21

Advertising
background image

21

Initial Installation

QUALIFIED INSTALLERS ONLY

V

ENTING

:

This fireplace has been tested and certified for use with SIMPSON DURAVENT DIRECT VENT TYPE “GS”

PIPE FOR GAS STOVES, SECURITY CHIMNEY’S SECURE VENT DIRECT VENT SYSTEM kits, AMERICAN

METAL PRODUCTS AMERIVENT DIRECT and DIRECT-TEMP SELKIRK METALBESTOS.
A 1” (25 mm) clearance to combustibles must be maintained around any vertical vent pipe. Around a

horizontal vent pipe, the clearance to combustibles should be 2” (51 mm) above and 11⁄2” (38 mm) on the

sides and bottom. When combustible materials are directly above a 90° elbow, 3” (76 mm) of clearance

are necessary (see Figure 28).

Table 7. Vent Pipe Minimum Clearances.

Vertical Pipe to

the Side Walls

Horizontal Pipe to

the Sides & Bottom

Above an Elbow

Above the Unit

Above an Elbow

Not Above the Unit

Above Horizontal

Vent Pipe

Wall Frame 8”

(203mm) or less

Hard

Pipe

1”

(25.4 mm)

11⁄2”

(38.1 mm)

3”

(76.2 mm)

3”

(76.2 mm)

2”

(51 mm)

10”x10”

(25x25cm)

Flex

Pipe

1”

(25.4 mm)

11⁄2”

(38.1 mm)

8”

(203 mm)

4 3⁄8”

(111 mm)

4 3⁄8”

(111 mm)

10”x10”

(25x25cm)

A 10” (254 mm) x 10” (254 mm) frame (see Figure 29) will assure the proper support and spacing for

the vent pipe as it passes through the wall. Installations in Canada require that a wall thimble be used

for passing through walls and ceilings. All sealing and vapour barriers must comply with local building

codes.
When planning an installation, it is necessary to select the proper

length of vent pipe for the particular requirements. The configuration

of the venting pipes depends on the locations of walls, ceilings,

and studs. However, the pipes cannot be of arbitrary length and

arrangement. Because the length of the vertical and horizontal

Figure 28. Vent Pipe Clearances.

2" (51mm)

3" (76mm)

41

3

/

4

"

(1048mm)

Figure 29. Vent Framing For Wall or Ceiling.

Figure 30. Wall/Ceiling Thimble provided.

WARNING: This gas appliance must not be connected

to a chimney flue serving a separate solid-burning

appliances.

sections

dramatically

affects the burning

efficiency

of

the

fireplace,

certain

guidelines

have

been set in I

NITIAL

I

NSTALLATION

- V

ENT

C

ONFIGURATIONS

AND

R

ESTRICTOR

S

ETTINGS

.

A two (2) piece wall/

ceiling

thimble

is

included with the stove

(see Figure 30).
Venting terminals can

not be recessed into a

wall or siding.