Initial installation – Enviro DV36 User Manual

Page 16

Advertising
background image

3"

(76mm)

12"

(305mm)

6"

(152mm)

14"

(356mm)

Top of unit

3” (76mm) mantle

10" (254mm) mantle

Combustible front face

3

/

4

" (19mm) facing board

Figure 23. Combustible Mantel Clearances for Fascia or

Insets.

Initial Installation

QUALIFIED INSTALLERS ONLY

16

A shelf may be installed above the unit. We

recommend that no heat sensitive items or

components be placed on the shelf (see

Figure 22).

M

ANTEL

C

LEARANCES

:

It is not necessary to install a mantel, but if one is desired it is important to follow the guidelines.
Note: Louvers have different mantel clearances than when fascia or insets are installed.

Table 3: Mantel clearances.

Louvers Only

Fascia or Insets

Top of unit to horizontal framing

3” (7.6 cm)

3” (7.6 cm)

Top of unit to bottom of 3” (7.6 cm) mantel

12” (30.5 cm)

Top of unit to bottom of 31⁄2” (8.9 cm) mantel

8” (20.3 cm

Top of unit to bottom of 10” (254 mm) mantel

10” (25.4 cm

14” (35.6 cm)

Top of unit to bottom of 3⁄4” (19 mm) facing board

6” (15.2 cm)

6” (15.2 cm)

3"

(76mm)

Top of unit

Combustible

front face

Combustible board

Figure 22. Combustible Shelf Clearance.

Figure 21. Raised Fireplace with no Hearth

Even though the DV36 can be installed at floor

level without a hearth, there are a few options

with raised fireplaces: raised with a floor level

hearth (Figures 19), raised with a raised hearth

(Figures 20), or raised with no hearth (Figures 21).

If the fireplace is raised, it cannot be placed within

37 inches (1.04 m) of the ceiling. When installing

a raised fireplace, it is imperative that the support

stand is strong enough to hold the weight of the

fireplace and venting.