7-1. TROUBLE SHOOTING GUIDE

Problem

Cause

Correction

SECTION 7. TROUBLESHOOTING

POWER switch ON but
fryer completely inoperative

Control error code “E-10”

Vat is under-filled

• Open circuit

• Open high limit circuit

• JIB is low or empty
• JIB oil line is clogged or

collapsed

• Filter pan needs cleaned

• Plug fryer in
• Check breaker or fuse at supply box
• Circuit breakers in fryer tripped-Open left

door and reset circuit breakers on fryer;
See below

• Reset the high limit by using a small

screwdriver or Allen wrench, gently
pushing it into the hole in the heating
element hinge; if high limit does not reset,
high limit may need replaced

• Fill the JIB
• Check JIB line
• Check JIB tube & connection
• Clean filter pan and change paper or pad