Henny Penny EEE-143 User Manual

Page 61

Advertising
background image

Model EEE-141,142, 143, 144

7-2. ERROR CODES

DISPLAY

CAUSE

CORRECTION

“E-21”

Slow heat recovery

Have a certified service technician check the fryer for correct
voltage to the unit; have the contactors and heating element
checked; have unit checked for loose or burnt wires

“E-22” “NO HEAT” Elements not

Check power cord and heat circuit

“CHECK PWR

heating

CORD AND
BREAKER”

“E-31”

Elements are up

Lower elements completely back into the vat

“E-41”, “E-46”

Programming

Turn switch to OFF, then back to ON; if display shows any

failure

of these error codes, have the controls re-initialized; if error code
persists, have the control board replaced

“E-47”

Analog converter

Turn switch to OFF, then back to ON; if “E-47” persists,

chip or 12 volt

have the I/O board, or the PC board replaced; if speaker

supply failure

tones are quiet, probably I/O board failure; have the I/O board
replaced

“E-48”

Input system

Turn switch to OFF, then back to ON; have controlPC board

error

replaced if “E-48” persists

“E-54C”

Temperature input

Turn switch to OFF, then back to ON; have control PC board

error

replaced if “E-54C” persists

“E-60”

AIF PC board not

Press power button to vat off and back on again if “E-60”

communicating with

persists, have the connector between the PC boards checked;

control PC board

replace AIF PC board or control PC board if necessary

7-4

909

Advertising