Model EEE-141,142, 143, 144

7-2. ERROR CODES

In the event of a control system failure, the digital display shows an
error message. The message codes are shown in the DISPLAY
column below. A constant tone is heard when an error code is
displayed, and to silence this tone, press any button.

DISPLAY

CAUSE

CORRECTION

“E-4”

Control board

Turn switch to OFF position, then turn switch back to ON;

overheating

if display shows “E-4”, the control board is getting too hot;
check the louvers on each side of the unit for obstructions

“E-5”

Oil

Turn switch to OFF position, then turn switch back to ON;

overheating

if display shows “E-5”, the heating circuits and temperature
probes should be checked

“E-6A”

Temperature

Turn switch to OFF position, then turn switch back to ON;

probe open

if display shows “E-6A”, the temperature probe should be
checked

“E-6B”

Temperature

Turn switch to OFF position, then turn switch back to ON;

probe shorted

if display shows “E-6B”, the temperature probe should be
checked

“E-10”

High limit

Reset the high limit by using a small screwdriver or Allen
wrench gently pushing it into the hole in the heating element
hinge; if high limit does not reset, high limit may need be replaced

“E-15”

Drain switch

Make sure drain knob is completely pushed-in; if E-15 persists,
have drain switch checked

“E-18-A”

Left level sensor open

Turn switch to OFF position, then turn switch back to ON;

“E-18-B”

Right level sensor open

if display still indicates a failed sensor, have the connectors checked

“E-18-C”

Both level sensors open at the control board; have sensor checked & replace if necessory