c) Pump-Out Timer (S4 dip switch 3 & 4)

CAUTION

Do not adjust S4 dip switch 3 off and S4 dip switch 4 on for this model.
Otherwise, pump motor does not rotate in the pump-out direction.

When a pump-out is called for, the pump motor stops after the preceding freeze cycle.
The pump motor restarts 2 seconds later in the reverse direction, taking water from the
bottom of the tank and forcing pressure against the check valve seat allowing water to
go through the check valve and down the drain. At the same time, water flows through
the small tube to power flush the float switch. The pump motor drains the water tank for
the time determined by the pump-out timer. The pump-out timer also acts in place of
the harvest timer during cycles with a pump-out. The pump-out timer is factory set, and
generally no adjustment is required. The pump-out timer control can be set to pump-out
for 10 or 20 seconds.

S4 Dip Switch Setting Time (seconds)

Inlet

Water

Valve

No. 3

No. 4

T1

T2

OFF

OFF

10

150

closed

ON

OFF

10

180

closed

OFF

ON

10

120

open

ON

ON

20

180

closed

T1: Time to drain the water tank
T2: Harvest timer at pump-out

d) Pump-Out Frequency Control (S4 dip switch 5 & 6)

The pump-out frequency control is factory set to drain the water tank every 10 cycles,
and generally no adjustment is required. However, where water quality is bad and the
icemaker needs a pump-out more often, the pump-out frequency can be adjusted. The
pump-out frequency control can be set to have a pump-out occur every cycle, or every
2, 5, or 10 cycles.

Timing of the first pump-out is dependent on S4 dip switch 5 & 6 settings. The first
pump-out is factory set to occur after the 11th freeze cycle. See the table below.

S4 Dip Switch Setting

Pump-Out

Frequency

1st Pump-Out

No. 5

No. 6

OFF

OFF

Every cycle

After 2nd freeze cycle

ON

OFF

Every 2 cycles

After 3rd freeze cycle

OFF

ON

Every 5 cycles

After 6th freeze cycle

ON

ON

Every 10 cycles

After 11th freeze cycle