C. bin control check, Thermostatic bin control check: km-1301sah-e, A) mechanical bin control check – Hoshizaki STACKABLE CRESCENT CUBER KM-1301SAH-E User Manual

Page 40

Advertising
background image

40

C. Bin Control Check

1. Thermostatic Bin Control Check: KM-1301SAH-E

To check the thermostatic bin control, follow the steps below.

CAUTION

When the ambient temperature is below 45°F (7°C), the thermostatic bin
control switch opens and shuts down the icemaker even if the ice storage bin
is empty. When the thermostat is set in the prohibited range, the icemaker
operates continuously even if the ice storage bin is filled with ice. Setting in the
prohibited range may result in severe damage to the icemaker.

The thermostatic bin control is factory set, and generally no adjustment is required.
However, adjustment may be needed in some conditions, particularly at higher altitude
locations. Note that when the thermostatic bin control switch is open, the control board
red "POWER OK" LED is off.

1) Turn off the power supply.
2) Remove the front panel, then move the control switch to the "OFF" position.
3) Clear any ice away from the thermostatic bin control bulb.
4) Remove the control box cover, then disconnect the thermostatic bin control wires from

the thermostatic bin control switch.

5) Hold your hand around the thermostatic bulb to warm it up.
6) Check for continuity across the thermostatic bin control switch. If closed, continue to

step 6. If open, adjust or replace the thermostatic bin control.

7) With the multimeter test leads still in place, hold ice on the thermostatic bin control bulb

to lower the temperature. Within 10 seconds, the thermostatic bin control switch should
open (no continuity). If it remains closed, adjust or replace the thermostatic bin control.

2. Mechanical Bin Control Check and Cleaning: KM-1301SWH-E, KM-1301SRH-E

a) Mechanical Bin Control Check

To check the mechanical bin control switch, follow the steps below.

1) Turn off the power supply.
2) Remove the front panel, then move the control switch to the "OFF" position.
3) Remove the control box cover, then clear any ice away from the mechanical bin control.
4) Check bin control cable and wire harness connections. See Fig. 1.
5) Disconnect the red connector from the control board RED K4 connector.
6) Check for continuity across the wires of the red connector. When the actuator paddle

is not engaged, the mechanical bin control switch is closed. If open, check that bin
control cable connector and the wire harness connector(s) are properly connected and
that the actuator paddle is not sticking. Clean if necessary. See "IV.C.2.b) Mechanical
Bin Control Cleaning." If the mechanical bin control switch still reads open, replace the
mechanical bin control.

Advertising
This manual is related to the following products: