E) harvest pump timer (s4 dip switch 7), F) factory use (s4 dip switch 8), G) freeze timer (s4 dip switch 9 & 10) – Hoshizaki STACKABLE CRESCENT CUBER KM-1301SAH-E User Manual

Page 23: Caution

Advertising
background image

23

e) Harvest Pump Timer (S4 dip switch 7)

CAUTION

Factory set for proper operation. Do not adjust. Adjustment outside of the
factory default setting may result in damage to the icemaker.

Depending on the harvest pump timer setting, the pump motor energizes and runs
the last 0 or 50 seconds of harvest. When the pump is on, water circulates over the
evaporator. The water valve is open during harvest for a maximum of 6 minutes or the
length of harvest minus 0 or 50 seconds (determined by the harvest pump timer setting),
whichever is shorter.
When S4 dip switch 7 is on, the pump motor is energized through the #5 pin (DBu wire)
on the control board K1 ten-pin connector and the X1 relay (auxiliary code T-0, U-0), X10
relay (auxiliary code U-1 and later). The #5 pin (DBu wire) is used in most applications
to reverse the pump motor or energize the drain valve in pump-out cycles. In this
application, it is used for the pump-out cycle (reverse rotation) as well as the harvest
pump timer (freeze rotation). Therefore, the harvest pump timer relays are needed to
control the pump motor direction during the pump-out and harvest cycles. See "III.B.
Wiring Diagrams."

S4 Dip Switch Setting

Pump Motor

Time (seconds)

No. 7

ON

50

OFF

0

f) Factory Use (S4 dip switch 8)

Factory set for proper operation. Do not adjust. This must be left in the factory default
position.

g) Freeze Timer (S4 dip switch 9 & 10)

CAUTION

Adjust to proper specification, or the unit may not operate correctly.

The freeze timer setting determines the maximum allowed freeze time to prevent possible
freeze-up issues. Upon termination of the freeze timer, the control board initiates the
harvest cycle. After 2 consecutive freeze timer terminations, the control board shuts down
the icemaker. In this case, see "IV.G.3. Low Ice Production" for possible solutions. The
freeze timer is factory set, and generally no adjustment is required. Before changing this
setting, contact Hoshizaki Technical Support at 1-800-233-1940 for recommendations.

S4 Dip Switch Setting

Time

(minutes)

No. 9

No. 10

OFF

OFF

60

OFF

ON

50

ON

OFF

70

ON

ON

60

Advertising