B. important notes for component replacement – Hoshizaki STACKABLE CRESCENT CUBER KM-1301SAH-E User Manual

Page 54

Advertising
background image

54

B. Important Notes for Component Replacement

CAUTION

When replacing a component listed below, see the notes to help ensure proper
operation.

Component

Notes

Compressor

Install a new start capacitor, run capacitor, and start relay.

Expansion Valve • Attach the expansion valve bulb to the suction line in the same location as the previous

bulb.

• The bulb should be between the 10 and 2 o'clock position on the tube.
• Secure the bulb with the clamp and holder, then insulate it.

Hot Gas Valve
Liquid Line Valve

• Replace the strainer when replacing the hot gas valve.
• Use copper tube of the same diameter and length when replacing valve lines.

Fan Motor

Install a new capacitor.

Pump Motor

Install a new capacitor.

Thermistor

• Attach the new thermistor to the suction line in the same location as the previous

thermistor.

• The thermistor should be at the 12 o'clock position on the tube.
• Smoothly fill the recessed area of the thermistor holder with high thermal conductive

type sealant. Hoshizaki America part number 4A0683-01 (Silicone Heat Sink Compound
10-8108 manufactured by GC Electronics), KE-4560 RTV (manufactured by ShinEtsu
Silicones), or equivalent are recommended.

• Secure the thermistor with the holder, then insulate it.
• Be very careful to prevent damage to the leads.

Thermistor Holder

Cable Tie

Thermistor Lead

Foam Insulation

Advertising