Km-1301swh-e (water-cooled) – Hoshizaki STACKABLE CRESCENT CUBER KM-1301SAH-E User Manual

Page 33

Advertising
background image

33

2. KM-1301SWH-E (water-cooled)

Note:
1. Pressure data is recorded at 5 minutes into freezing cycle. The data not in

bold

should be used for reference only.

2. We reserve the right to make changes in specifications and design without prior

notice.

70/21

1330

603

1304

591

1239

562

80/27

1310

594

1269

576

1189

539

90/32

1304

591

1240

562

1165

528

lbs./day kg./day

100/38

1281

581

1222

554

1096

497

70/21
80/27
90/32

watts

100/38

70/21

1335

5.05

1425

5.40

1971

7.46

80/27

1404

5.31

1544

5.85

2324

8.80

90/32

1425

5.40

1643

6.22

2335

8.84

gal./day m

3

/day

100/38

1741

6.59

1805

6.83

2971

11.25

70/21
80/27
90/32

min.

100/38

70/21
80/27
90/32

min.

100/38

70/21

238

16.7

239

16.8

249

17.5

80/27

239

16.8

240

16.9

256

18.0

90/32

239

16.8

241

16.9

255

17.9

PSIG kg/cm

2

G

100/38

244

17.2

244

17.2

267

18.8

70/21

50

3.5

51

3.6

52

3.6

80/27

50

3.5

51

3.6

52

3.7

90/32

51

3.6

52

3.7

53

3.7

PSIG kg/cm

2

G

100/38

51

3.6

52

3.7

54

3.8

19,382 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]

TOTAL HEAT OF REJECTION FROM COMPRESSOR

2,600 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]

WATER FLOW FOR CONDENSER

117 gal./h [AT 100ºF (38ºC) / WT 90ºF (32ºC)]

PRESSURE DROP OF COOLING WATER LINE

less than 10 PSIG

32

34

32
33

34

32
33

2.4

4.2

3.1

3.7
3.0
2.4

3.8

31

APPROXIMATE ICE

PRODUCTION PER 24 HR.

APPROXIMATE ELECTRIC

CONSUMPTION

APPROXIMATE WATER

CONSUMPTION PER 24 HR.

FREEZING CYCLE TIME

WATER TEMP. (ºF/ºC)

AMBIENT TEMP.

(ºF/ºC)

50/10

70/21

90/32

1790

1780
1780
1780
1786

1780
1780
1780

34
35
36
38

1799
1810
1806
1830

HARVEST CYCLE TIME

HEAD PRESSURE

3.4
2.9

3.7

2.2
2.1

TOTAL HEAT OF REJECTION FROM CONDENSER

SUCTION PRESSURE

Advertising
This manual is related to the following products: