Freeze Up - Possible Cause

Freeze Cycle

1. Evaporator

a) Scaled up.
b) Damaged.

2. Separators

a) Out of position.

3. Spray Tubes and/or Spray

Guides

a) Dirty.
b) Out of position.

4. Refrigerant charge.

a) Low.

5. Check Valve

a) Defective.

6. Control Board

See "IV.B. Control Board Check."

a) Freeze timer set incorrectly.
b) Defective.

7. Inlet Water Valve

a) Leaking by.

8. Float Switch

See "IV.D. Float Switch Check
and Cleaning."

a) Float does not move freely.
b) Defective.

9. Pump Motor

a) RPM too slow.

10. Expansion Valve (TXV)

a) Defective.

11. Headmaster (C.P.R.) (remote

condenser unit)

a) Defective.

12. Water Regulating Valve

(water-cooled model)
See "IV.F. Adjustment of Water
Regulating Valve."

a) Out of adjustment.