Nec 2 of 5 redundancy, Nec 2 of 5 message length – Honeywell VOYAGER 1250G User Manual

Page 110

Advertising
background image

6 - 14

When Check Digit is set to Validate and Transmit, the scanner only reads
NEC 2 of 5 bar codes printed with a check digit, and will transmit this digit
at the end of the scanned data.

Default = No Check Digit.

NEC 2 of 5 Redundancy

If you are encountering errors when reading NEC 2 of 5 bar codes, you
may want to adjust the redundancy count. Redundancy adjusts the num-
ber of times a bar code is decoded before transmission, which may reduce
the number of errors. Note that the higher the redundancy count, the lon-
ger it will take to decode the bar code. To adjust the redundancy, scan the
NEC 2 of 5 Redundancy bar code below, then scan a redundancy count
between 0 and 10 on the

Programming Chart

inside the back cover of this

manual. Then scan the

Save

bar code.

Default = 0.

NEC 2 of 5 Message Length

Scan the bar codes below to change the message length. Refer to

Message Length Description

(page 6-2) for additional information. Mini-

mum and Maximum lengths = 1-80. Minimum Default = 3, Maximum
Default = 80.

* No Check Digit

Validate and Transmit

Validate, but Don’t Transmit

NEC 2 of 5 Redundancy

Minimum Message Length

Maximum Message Length

Advertising